Maintenance and service -> Start battery for Your Volvo Xc90 SUV 2020

MAINTENANCE AND SERVICE  
Start battery  
Connection points  
WARNING  
The vehicle has a single-pole electrical sys-  
tem that uses the chassis and engine mount  
as conductors.  
Batteries generate hydrogen gas,  
which is flammable and explosive.  
WARNING  
California Proposition 65  
Do not connect the jumper cable to  
any part of the fuel system or to any  
moving parts. Avoid touching hot  
manifolds.  
The start battery is used to start the electrical  
system and power the starter motor and  
other electrical equipment in the vehicle.  
Operating, servicing and maintaining a pas-  
senger vehicle can expose you to chemi-  
cals including engine exhaust, carbon mon-  
oxide, phthalates, and lead, which are  
known to the State of California to cause  
cancer and birth defects or other reproduc-  
tive harm. To minimize exposure, avoid  
breathing exhaust, do not idle the engine  
except as necessary, service your vehicle in  
a well ventilated area and wear gloves or  
wash your hands frequently when servicing  
your vehicle. For more information go to  
The start battery should only be replaced by a  
Battery fluid contains sulfuric acid. Do  
not allow battery fluid to contact eyes,  
skin, fabrics or painted surfaces.  
workshop22  
.
The vehicle has a voltage-regulated alternating  
current generator.  
If contact occurs, flush the affected  
area immediately with water. Obtain  
medical help immediately if eyes are  
affected.  
The start battery is a 12 V battery, dimen-  
sioned for the carbon dioxide-reducing func-  
tions Start/Stop and regenerative charging  
and to support the function of the vehicle's  
various systems.  
Never expose the battery to open flame  
or electric spark. Do not smoke near  
the battery. Failure to follow the  
instructions for jump starting can lead  
to injury.  
The service life and performance of the start  
battery are affected by factors such as driving  
style, driving conditions, climate, battery dis-  
charges, number of starts, etc.  
Use the vehicle's connection points in the  
engine compartment to connect an external  
start battery or battery charger.  
The battery terminals on the car's start battery  
in the luggage/cargo area must not be used.  
Never disconnect the start battery while  
the engine is running.  
If the start battery is being charged, the sup-  
port battery will also be charged.  
Make sure the cables to the start battery  
are correctly connected and the clamps  
are securely tightened.  
22  
An authorized Volvo workshop is recommended.  
}}  
595  
 
MAINTENANCE AND SERVICE  
||  
Failure to observe the following could  
cause the infotainment energy save mode  
to temporarily stop working and/or a mes-  
sage in the driver's display regarding the  
state of charge of the starter battery may  
be temporarily incorrect after an external  
starter battery or battery charger has been  
connected:  
If the starter battery becomes discharged  
too many times, it will shorten its service  
life.  
The service life of the starter battery is  
affected by several factors, such as driving  
conditions and climate. The starting  
capacity of the battery reduces gradually  
over time. The battery must therefore be  
recharged if the vehicle is not used or a  
long period of time or if it is only driven  
short distances. Severe cold further limits  
the starting capacity.  
The negative battery terminal of the  
vehicle's starter battery must never be  
used to connect an external starter  
battery or battery charger – only the  
vehicle's negative charging point  
should be used as a grounding point.  
Positive connection point  
Negative connection point  
To keep the starter battery in a good condi-  
tion, the vehicle should be driven at least  
15 minutes per week or the battery should  
be connected to a battery charger with  
automatic trickle charging.  
Only a modern battery charger with con-  
trolled charge voltage should be used to  
charge the starter battery and support bat-  
tery. The rapid charging function should  
not be used as this could damage the bat-  
tery.  
A starter battery that is always kept fully  
charged has the maximum service life.  
596  
MAINTENANCE AND SERVICE  
Location  
WARNING  
If the starter battery is disconnected, the  
function for automatic opening and closing  
must be reset to function correctly. A reset  
is required in order for the pinch protection  
to work.  
On certain models, the battery is secured  
with a tensioning strap. Make sure that the  
tensioning strap is always securely tight-  
ened.  
The start battery is located in the cargo compart-  
ment.  
Specifications for start battery  
Battery type  
H7 AGM  
H8 AGM  
12  
Voltage (V)  
12  
Cold start capacityA - CCAB (A)  
Dimensions, L×W×H  
Capacity (Ah)  
800  
850  
315×175×190 mm (12.4×6.9×7.5 inches)  
80  
353×175×190 mm (13.9×6.9×7.5 inches)  
95  
A
According to EN standard.  
Cold Cranking Amperes.  
B
Volvo recommends that batteries are replaced  
by an authorized Volvo workshop.  
}}  
597  
MAINTENANCE AND SERVICE  
||  
If replacing the battery, make sure you  
replace it with a battery of the same size,  
cold start capacity and type as the original  
battery (see the decal on the battery).  
Related information  
Jump starting using another battery  
(p. 435)  
Reset procedure for pinch protection  
(p. 169)  
598  
MAINTENANCE AND SERVICE  
Support battery  
Vehicles with the Start/Stop function are  
equipped with two batteries – a more power-  
ful 12 V start battery and a support battery  
that provides stronger current during the  
function's start sequence.  
The higher the current consumption in  
the vehicle, the more the alternator has  
to work and the batteries have to be  
charged = increased fuel consumption.  
When the starter battery capacity has  
dropped below the lowest permissible  
level, the Start/Stop function is disen-  
gaged.  
When the Start/Stop function is temporarily  
reduced due to high current consumption:  
If the vehicle is instead equipped with a 48 V support  
battery, it is located under the cargo compartment.  
The box over the 48 V support battery may only be  
removed by an authorized workshop.  
The engine will auto-start, even if the  
driver does not lift their foot from the  
brake pedal.  
WARNING  
The support battery does not normally require  
more service than the start battery. If you have  
any questions or concerns, consult a work-  
shop an authorized Volvo workshop is rec-  
ommended.  
High voltage may be dangerous if handled  
incorrectly. Do not touch anything on bat-  
teries that is not clearly described in this  
Owner's Manual.  
The 12 V support battery is located in a box next to  
the spring strut in the engine compartment.  
Never use a 48 V support battery to  
jump start the vehicle.  
External electrical equipment may not  
under any circumstance be connected  
to the 48 V battery.  
Only a workshop may replace or per-  
form service on the 48 V battery – an  
authorized Volvo workshop is recom-  
mended.  
}}  
599  
 
MAINTENANCE AND SERVICE  
||  
Cold start capacityA -  
CCAB (A)  
170  
If the following is not observed, the Start/  
Stop function may temporarily stop work-  
ing after connection of an external starter  
battery or battery charger:  
If the starter battery has been discharged  
to the extent that the vehicle does not have  
normal electrical functions and the engine  
must then be jump-started with an external  
battery or a battery charger, the Start/Stop  
function may remain activated. If the Start/  
Stop function shortly thereafter auto-stops  
the engine, there is a huge risk that auto-  
start of the engine will fail due to insuffi-  
cient battery capacity since the battery had  
not had time to recharge.  
150×90×130 mm  
(5.9×3.5×5.1  
inches)  
Dimensions, L×W×H  
The negative battery terminal of the  
vehicle's starter battery must never be  
used to connect an external starter  
battery or battery charger – only the  
vehicle's negative charging point  
should be used as a grounding point.  
Capacity (Ah)  
10  
A
According to EN standard.  
Cold Cranking Amperes.  
B
If replacing the battery, make sure you  
replace it with a battery of the same size,  
cold start capacity and type as the original  
battery (see the decal on the battery).  
If the vehicle has been jump-started or if  
there has not been enough time for the  
battery to be charged with a battery  
charger, the Start/Stop function should be  
temporarily deactivated until the battery  
has been recharged by the vehicle. At an  
ambient temperature of about +15°C  
(about 60°F), the battery must be charged  
by the vehicle for at least one hour. At  
lower ambient temperatures, the charging  
time can increase to 3-4 hours. It is advisa-  
ble to charge the battery with an external  
battery charger.  
Related information  
Start/Stop function (p. 416)  
Specifications for support battery  
Type  
AGM  
Voltage (V)  
12  
600  
MAINTENANCE AND SERVICE  
Battery symbols  
There are warning symbols and information  
on the batteries.  
Battery recycling  
Start batteries and support batteries contain  
lead and must be recycled in an environmen-  
tally sound manner at the end of their service  
life.  
Avoid smoking, open  
flames, and/or sparks.  
Consult a workshop if you are uncertain of  
how to dispose of this type of waste an  
authorized Volvo workshop is recommended.  
Wear protective goggles.  
Related information  
Risk of explosion.  
Recycle properly.  
See the Owner's Manual  
for additional information.  
Keep batteries away from  
children.  
Related information  
Batteries contain corro-  
sive acid.  
601